TPU material,similar material as PU strips,ensure the adhesive property between end caps and IP68 waterproof led srtips.Plastic end caps are anti-uv,and are not easy to be broken,at least can be used for 5 years . With transparent and frosted suface,it won't be obvious shadow to tell apart.We can't make sure the normal length of led strips is proper in anywhere,the end caps are designed to solve these problem.After cutting needless strips,use end caps to plug ,and seal with glue.There are two end caps attched to each led srtip.The caps are only included with strip light to sell,not sold separately as well. Led Strip Cap,Plastic Caps,Ip68 Strip Cap,Waterproof End Cap Guangdong Kamtat Lighting Technology Joint Stock Co., Ltd. , http://www.ip68ledstrip.com
++++General
Farady Powertech strives to bring our customers the latest technology and competitive pricing and best service for pole mounted Auto circuit recloser
The FAR series Auto circuit recloser can use on overhead distribution lines as well as distribution substation applications for all voltage classes 11kV up to 38kV at 50/60HZ power system. And its rated current can reach 1600A.
The FAR series Auto circuit recloser integrates the functions of control, protection, measurement,communication,fault detection,on-line monitoring of closing or opening.comply to IEC62271 and ANSI/IEEE C37.60 standard
++++Service environment
a) Air temperature: Maximum temperature: +85ºC; Minimum temperature:-45ºC
b) Humidity: Monthly average humidity 95%; Daily average humidity 90% .
c) Altitude above sea level: Maximum installation altitude: 2500m or more higher.
d) Ambient air not apparently polluted by corrosive and flammable gas, vapor etc.
e) No frequent violent shake
++++Technical data
Â
No.
Item
Unit
data
1
Rated voltage
kV
15
27
38
2
Rated current
A
630
1250
1600
3
Rated frequency
HZ
50/60
4
Power frequency 1min
Dry
kV
50
65
85
Wet
45
55
75
5
Lightning impulse withstand voltage(peak value)alternate, opposite/fracture
kV
110
150
170
6
Rated short circuit breaking current
kA
20
16/25
12.5
7
Rated short current switching current(peak value)
kA
50
40/63
31.5
8
Rated peak value withstand current
kA
50
40/63
31.5
9
4S short time withstand current
kA
20
16/25
12.5
10
Rated operating circulate
Â
O-T1-CO-T2-CO-T3-CO-T4-CO
11
Breaking current frequency under rated short circuit
times
30
12
Mechanism life
times
10000
13
Secondary loop 1 min power frequency withstand voltage
kV
2
++++Outline & Sizes for FAR
++++General
Farady Powertech strives to bring our customers the latest technology and competitive pricing and best service for pole mounted Auto circuit recloser
The FAR series Auto circuit recloser can use on overhead distribution lines as well as distribution substation applications for all voltage classes 11kV up to 38kV at 50/60HZ power system. And its rated current can reach 1600A.
The FAR series Auto circuit recloser integrates the functions of control, protection, measurement,communication,fault detection,on-line monitoring of closing or opening.comply to IEC62271 and ANSI/IEEE C37.60 standard
++++Service environment
a) Air temperature: Maximum temperature: +85ºC; Minimum temperature:-45ºC
b) Humidity: Monthly average humidity 95%; Daily average humidity 90% .
c) Altitude above sea level: Maximum installation altitude: 2500m or more higher.
d) Ambient air not apparently polluted by corrosive and flammable gas, vapor etc.
e) No frequent violent shake
++++Technical data
Â
No.
Item
Unit
data
1
Rated voltage
kV
15
27
38
2
Rated current
A
630
1250
1600
3
Rated frequency
HZ
50/60
4
Power frequency 1min
Dry
kV
50
65
85
Wet
45
55
75
5
Lightning impulse withstand voltage(peak value)alternate, opposite/fracture
kV
110
150
170
6
Rated short circuit breaking current
kA
20
16/25
12.5
7
Rated short current switching current(peak value)
kA
50
40/63
31.5
8
Rated peak value withstand current
kA
50
40/63
31.5
9
4S short time withstand current
kA
20
16/25
12.5
10
Rated operating circulate
Â
O-T1-CO-T2-CO-T3-CO-T4-CO
11
Breaking current frequency under rated short circuit
times
30
12
Mechanism life
times
10000
13
Secondary loop 1 min power frequency withstand voltage
kV
2
++++Outline & Sizes for FAR
Model NO.: FAR
Poles Number: 3
Type: Circuit Breaker
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection)
Certification: VDE, ISO9001-2000, Type Tested
Trademark: FARADY
Transport Package: Wooden Case
Origin: Zhejiang, China
HS Code: 8535900090
Model NO.: FAR
Poles Number: 3
Type: Circuit Breaker
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection)
Certification: VDE, ISO9001-2000, Type Tested
Trademark: FARADY
Transport Package: Wooden Case
Origin: Zhejiang, China
HS Code: 8535900090